CHAPTER 6
Installing, Removing, and Verifying Field
Replaceable Units
• Installing a Supervisor Module, on page 113
• Removing a Supervisor Module, on page 115
• Nondisruptive Migration for Supervisor Modules, on page 117
• Disruptive Migration for Supervisor Modules, on page 150
• Crossbar Fabric Switching Modules, on page 156
• Nondisruptive Migration from Crossbar Fabric-1 Switching Modules to Crossbar Fabric-3 Switching
Modules, on page 162
• Power Supply in a Switch Chassis, on page 168
• Installing and Removing Fan Modules, on page 175
• Powering up the Switch and Verifying the Component Installation, on page 178
Installing a Supervisor Module
To install a supervisor module on a Cisco MDS 9700 Series chassis, follow these steps:
Before you begin
• You must follow the ESD protocols, including the following:
• You must wear a grounded ESD wristband (or other personal grounding device) whenever you
handle the electronic modules outside the grounded chassis.
• You must carry electronic modules only by their covered edges or handles. Do not touch their
electronic components.
• Whenever a module is outside a grounded chassis, place it flat on an antistatic surface or in an
antistatic bag. Never lean the module on anything, or place anything else on top of the module.
• Verify that the chassis is grounded.
• Verify that you have the following tools and equipment:
• ESD wrist strap (or other personal grounding device)
• Number 1 Phillips torque screwdriver
Cisco MDS 9700 Series Switches Hardware Installation Guide