EasyManuals Logo
Home>Cisco>Switch>MDS 9700 Series

Cisco MDS 9700 Series User Manual

Cisco MDS 9700 Series
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
Table 11: Cisco MDS 9700 Series 24/10 Port SAN Extension Module LEDs
DescriptionStatusLED
All diagnostics pass. The module is operational (normal initialization
sequence).
GreenStatus
One of the following occurs or occurred:
• The module is booting or running diagnostics (normal initialization
sequence).
• An over temperature condition has occurred. (A minor temperature
threshold has been exceeded during environmental monitoring.)
Orange
One of the following occurs:
• The module is resetting. The switch has just been powered on or
the module has been hot inserted during the normal initialization
sequence.
• An over temperature condition has occurred (a major temperature
threshold has been exceeded during environmental monitoring).
• If the module fails to download the code and configuration
information successfully during the initial reset, the LED stays
blinking red; the module does not come online.
Blinking Red
The module has detected a slot ID parity error on the mid plane. The
module cannot determine its slot number and hence will not respond to
the Supervisor.
Solid Red
The operator has activated this LED to identify this module in the chassis.
Blinking blueID
This module is not being identified.Off
Link is up.
Solid greenLink
Port Beacon On (beacon is used to identify port).Steady Blinking
Green
Link is up (traffic on port).Intermittent
Blinking Green
SFP is not present or Admin is down.Solid Orange
A fault condition exists.Blinking Orange
The port is not active or the link is not connected.Off
3
3
The Link LED status of IP Storage ports indicates Solid Orange when an SFP is present and the link is
not connected.
Fiber Channel over Ethernet Switching Modules
The following section describes the fiber channel over Ethernet switching modules.
Cisco MDS 9700 Series Switches Hardware Installation Guide
48
Product Overview
Fiber Channel over Ethernet Switching Modules

Table of Contents

Other manuals for Cisco MDS 9700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9700 Series and is the answer not in the manual?

Cisco MDS 9700 Series Specifications

General IconGeneral
BrandCisco
ModelMDS 9700 Series
CategorySwitch
LanguageEnglish

Related product manuals