switch(config)# copy usb1:licenses_archive_file_name.tar bootflash:switch_license.tar
Copy progress 100% 10KB
Copy complete, now saving to disk (please wait)...
switch(config)# copy bootflash:switch_license.tar bootflash:switch_license.lic
Copy progress 100% 10KB
Copy complete, now saving to disk (please wait)...
switch(config)# install license bootflash:switch_license.lic
Installing license...........................done
switch# show license usage
Feature Ins Lic Status Expiry Date Comments
Count
--------------------------------------------------------------------------------
IOA_X9334 No 0 In use Grace 115D 2H
FM_SERVER_PKG No - Unused -
MAINFRAME_PKG No - Unused -
ENTERPRISE_PKG Yes - Unused never -
SAN_ANALYTICS_PKG No - In use Grace 119D 20H
SAN_TELEMETRY_PKG No - Unused Grace 109D 1H
Step 13 If the standby Supervisor-1 Module is not in the powered down state, then put the standby Supervisor-1 Module to out
of service, using the out-of-service module slot command .
Where a slot indicates the chassis slot number in which the standby supervisor module resides.
switch(config)# out-of-service module 6
Step 14 Remove the Supervisor -1 Module from the chassis.
Refer the “Verification” section to verify that the Supervisor-1 Module configurations are successfully applied to the
Supervisor-4 Module.
To view the inventory information for modules from the Cisco DCNM Web UI, Choose Inventory > View > Modules.
The Modules window is displayed with a list of all the switches and its details for a selected scope.
For more information, see the Cisco DCNM SAN Management Configuration Guide.
What to do next
Migrate the Crossbar Fabric-1 Switching Modules to Crossbar Fabric-3 Switching Modules. For more
information, see the “Nondisruptive Migration from Crossbar Fabric-1 Switching Modules to Crossbar Fabric-3
Switching Modules” section
Verification
Use the following show commands to verify the migration procedure for the Supervisor-4 Module:
• show version
• show module
• show interface brief
Cisco MDS 9700 Series Switches Hardware Installation Guide
138
Installing, Removing, and Verifying Field Replaceable Units
Verification