256
INJECTION
SPECIAL FEATURES: CHECKING THE ADDITIVE LEVEL
IMPERATIVE: Respect the safety and cleanliness requirements.
Preliminary operation.
Place the vehicle on a 2-column lift.
Raise and support the vehicle.
Remove:
- The heat shield from the additive reservoir.
- The additive reservoir (see corresponding operation).
Checks.
Empty the reservoir into a clean glass container.
Measure the quantity of additive and compare it with the table below.
Additional operation.
Refit the additive reservoir (see corresponding operation).
Top up the additive reservoir.
Refit the heat shield to the additive reservoir.
Perform the actuator test «filling the tube: additive pump - additive injector» using LEXIA or PROXIA.
Distance travelled by the vehicle Quantity of additive taken from the additive reservoir (Litres)
Kilometres Miles 9HY - 9HZ RHR
00 2,2 + 0,2 2,8 + 0,2
30 000 18 750 1,17 + 0,2 2,17 + 0,2
60 000 37 500 1,25 + 0,2 1,55 + 0,2
90 000 56 250 0,77 + 0,2 0,92 + 0,2
120 000 75 000 0,3 + 0,2 0,3 + 0,2