EasyManuals Logo

CITROEN C4 2004 User Manual

CITROEN C4 2004
412 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #264 background imageLoading...
Page #264 background image
261
INJECTION
CHECKING THE AIR SUPPLY CIRCUIT
Tools.
[1] Manual pressure-vacuum pump :FACOM DA 16
Chec
ks.
Vacuum pump.
Connect the tool [1] onto the vacuum pump (1).
Start the engine.
The vacuum value should be 0.9 ± 0.1 bar at idle (after 30 seconds of operation).
NOTE: The exhaust gas recycling valve is not linked to the air supply circuit.
The exhaust gas recycling electrovalve is controlled by the engine ECU.
Turbocharging pressure regulation valve.
- Connect the tool [1] on the valve (2).
- Appy a vacuum of approx. 0.8 bar.
- Rod "a" should move 6 ± 2 mm.
B1HP1UGC
B1HP22RC
Engine: 9HX
UK-C4-page238-270-2004 15/11/04 9:18 Page 261