Service manual OEB/OES/OGB/OGS
5_00e Troubleshooting list_L 16/27 2013-01-30
OEB
OES
OGB
OGS
Defect
Possible cause or remedy
5.2.8 Water drips out of the
front area of the appliance
floor in table-top models
Seak between inner and outer housing is worn
or missing Check seal groove for door seal
Channel seal between appliance drip tray and
housing is missing
Door seal worn
5.2.9 Too dry or too wet in
programmes with steam
Pressure balance valve in oven ceiling open
check and adjust, if necessary, clean
Pressure balance valve in oven ceiling
blocked Clean with hand shower
Solenoid valves are not closing properly
Bypass sensor greased up / Bypass opening
blocked (not with OES 6.06)
Demoisturisation activated
5.3 Steam generator
5.3.1 Steam generator is still
not ready to operate after 5
mins.
Check polarity of the B4 sensor connection
(green/white)
Overfilling of the steam generator
Heater contactors do not pull in
a) Contact problem on terminals
b) Heater contactor defective
Immersion heater / heat exchanger in the
steam generator calcified
Immersion heater defective
5.3.2 Uncontrolled steam
supply in stop mode, and
moisture in the convection
programme
Check polarity of the B4 sensor connection
(green/white)
Steam generator or pre-heating sensor
calcified see 4.4 Decalcifying the
CONVOTHERM
Pre-heating temperature set too high in c01
Electronics’ temperature detection defective
( Replace control module CM)
5.3.3 Steam generator is no
long switching off
Check polarity of the B5 sensor connection
(green/white)
Bypass pipe has come loose
Bypass pipe T-piece and B5 blocked or
greased up
Constant water supply in the condenser
Electronics service programme c 05 on
permanent steaming
Short circuit of the B5 sensor wiring
5.3.4 No water supply in the
steam generator
Water supply pipe closed
Injection part in non-return flow device
contaminated