Service manual OEB/OES/OGB/OGS
AS/11-2011 3_03e Emergency programmes_c
Emergency programme table:
X Operation possible
- Operation no longer possible
Error
no.
Message in
the display
O
E
S
6.06
O
E
B
O
E
S
O
G
B
O
G
S
Comments
E01.0 Not enough water X X X X X - - up to
180°C
- up to
180°C
up to
180°C
No programme with
steam
E02.0 Elec. temp. too
high
X X X X X X up to
140°C
up to
140°C
up to
140°C
up to
140°C
up to
140°C
*
5
E03.0 Fan malfunction
X*
2
X - X - up to
100°C*
- - - - - *
E04.0 Elec. fan
malfunction
X X X X X X up to
140°C
up to
140°C
up to
140°C
up to
140°C
up to
140°C
*
5
E05.0 No gas
X*
2
X*
2
X*
2
- -
E15.0 Excessive
condenser
temperature
X X X X X - - up to
180°C*
3
- up to
180°C*
3
up to
180°C*
3
E21.0 Oven sensor failure
- X - X - only
100°C
- - - - -
E22.0 CTS faulty X X X X X X X X X X X no CTS operation
E23.0 SG sensor failure
X*
2
X
X*
2
X
2
no OR*
4
no OR*
4
X
no OR*
4
X
no OR*
4
When regenerating
with steam
programme pre-heat
E24.0 Bypass sensor
failure
X*
2
X X X X up to
99°C
- X - X X
convectio
n only
When steaming
longer cooking time
possible
E25.0 Condenser sensor
failure
X X X X X
X*
3
up to
180°C*
3
up to
180°C*
3
up to
180°C*
3
up to
180°C*
3
up to
180°C*
3
E26.0 STL SG sensor
failure
X*
2
X
X*
2
X
X*
2
X X X X X X
*
6
E23.0 &
E26.0
STL SG and SG
sensor failure
X*
2
X
X*
2
X
X*
2
no OR*
4
no OR*
4
X - X
no OR*
4
*
6
E27.0 Excessive temp.
SG heater
X*
2
-
X*
2
-
X*
2
E33.0 SG heater error
X*
2
X
X*
2
X
X*
2
- - X - X X Only convection
possible
E34.0 SG pump error
X*
2
X
X*
2
X
X*
2
X X X X X X No limitation with
cooking mode*
7
E81.0 Programme
memory error
X X X X X X X X X X X
E82.0 WP error X X X X X X X X X X X
E83.0 Alg. error X X X X X X X X X X X
Error normally
remedied after
switching the
appliance off and on
again
E89.0 IDM error X X X X X X X X X X X
- IDM error X X X X X X X X X X X
- Lack of cleaning
agent pressure
X*
2
X X X X X X X X X X No CONVOClean
system possible
* Cooking time lengthened considerably. Dishes in the upper containers are ready first
*
2
Error message does not exist with this appliance type and therefore operation is not restricted by this
error.
(Restrictions in the table only apply for the another appliance types.)
*
3
Injection of water into the condenser is permanently activated (higher water consumption)
*
4
Operational readiness (=OR) i.e. steam generator’s pre-heating circuit remains inactive
*
5
Let appliance cool down or finish cooking at a lower oven temperature.
*
6
No protection against burning out the heater in the OEB (in the OGB also no mechanical STL)
*
7
As no automatic steam generator flushing is possible, risk of premature and further reaching appliance
defects