The hand s
hower can only be used for cleaning the oven and not for
cleaning the outer casing! Do not spray the inlet and outlet ventilation
openings and not on the electric current conducting unit parts of the
combination oven steamer.
Cleaning and maintenance work can only be performed on a cold unit!
Never spray into a hot oven with the hand shower! Allow CONVOTHERM to
cool to under 100°C oven temperature.
When cleaning the CONVOTHERM never use a high pressure cleaner or
water jet!
Never use acid on the combination oven steamer or expose to acidic steam
because the stainless steel can corrode.
To avoid discolouration and corrosion of the stainless steel, the combination
oven steamer must be cleaned regularly, also when only operated in the
steaming programmes.
Please make sure that the suction panel and the hanging rack are installed
and fastened according to the instructions.
Regular cleaning reduces the risk of damage due to low pressure.
Do not spray cleaner into the steam generator / steam outlet opening.
To avoid wear on the condenser and heavy grime build up on the oven floor,
use the grease drip tray when cooking greasy products (i.e.chicken).
Damage caused by improper cleaning, voids the guarantee.
4.3.2 Half-automatic oven cleaning
Safety:
When cleaning, wear proper protection (gloves and protective glasses are
included in every unit).
Do not inhale spray mist!
Do not allow the spray container to stand for longer periods of time under
pressure. Turn pump top slowly off and release the air pressure.
Nozzle, nozzle extension and nozzle parts should be rinsed clean after each
use.
Rinse out cleaner container weekly.
Operation instructions: Half-automatic oven cleaning
The CONVOTHERM is equipped with an oven cleaning programme „clean“.
1. Press
key → Selection possibilities are indicated in display. With the
selector knob choose‚Cleaning’
and press to confirm.
2. Confirm ‚Yes’ with the
key. → The symbol lights up and the selected
values of the cleaning programme are indicated in the display.
3. Press
key → The CONVOTHERM will start cleaning.
AS/11-2011 4_03e_Cleaning the Unit_c
Page 2 / 7