6.2.5 0-6* Password
Dene password access to menus.
0-60 Main Menu Password
Option: Function:
[Size
related] *
Dene the password for access to the Main Menu
via the [Main Menu] key. If parameter 0-61 Access
to Main Menu w/o Password is set to [0] Full access,
this parameter will be ignored.
0-60 Main Menu Password
Range: Function:
100 * [0 - 999 ]
0-65 Quick Menu Password
Option: Function:
Dene the password for access to the Quick Menu via
the [Quick Menu] key. If parameter 0-66 Access to Quick
Menu w/o Password is set to [0] Full access, this
parameter will be ignored.
0-66 Access to Quick Menu w/o Password
Option: Function:
NOTICE!
If parameter 0-61 Access to Main Menu
w/o Password is set to [0] Full access, this
parameter will be ignored.
[ 0] * Full access Disables the password dened in
parameter 0-65 Quick Menu Password.
[1] Read only Prevents unauthorized editing of Quick Menu
parameters.
[2] No access Prevents unauthorized viewing and editing of
Quick Menu parameters.
Parameter Descriptions
VLT
®
Compressor Drives CDS 302/CDS 303
52 Danfoss A/S © Rev. 2013-07-03 All rights reserved. MG34M422
6
6