Scanning Features
Product Reference Guide
283
Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in
100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setti
ng is
in 100ms increments). Pad
the result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
3. Go to
page 74 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT FLA
S
H ON TIME SETTING.
5. Scan the appropriate two digits from the keypad in
Appendix D, Keypad
representing the duration which was determined in the steps above.
You wi
ll hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See Table 43 for examples of how to set this
feature.
Table 43. Flash On Time Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
500ms 1,000ms (1 sec.)
5200ms (5.2
sec.
)
9,900ms (9.9 sec.)
2
Divide by 100 (and pad
with leading zeroes to yield
two digits
)
05 10 52 99
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT FLASH ON TIME SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘5 ‘1’ and ‘0 ‘5’ and ‘2’ ‘9’ and ‘9’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PM9500 and is the answer not in the manual?

Datalogic PowerScan PM9500 Specifications

General IconGeneral
TypeHandheld bar code reader
Wavelength680 nm
Sensor type-
Scanner type1D/2D
Tilt reading angle0 - 360 °
Pitch reading angle-40 - 40 °
Light levels (direct sunlight)0 - 100000 lx
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked Omnidirectional, MaxiCode, Micro QR Code, MicroPDF417, PDF417, QR Code
Wireless range150 m
Operating frequency910 MHz
Standard interfacesUSB, RS-232, RS-485
Connectivity technologyWireless
CertificationIEC 60825 Class 2 IEC 62471 Class 1 LED
Product colorBlack, Yellow
LED indicatorsYes
Protection featuresShock resistant
International Protection (IP) codeIP65
Sustainability certificatesRoHS
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Battery life10 h
Charging time4 h
Input voltage12 V
Battery capacity2150 mAh
Power consumption150 mA
Power source typeBattery
Cables includedNo
Weight and Dimensions IconWeight and Dimensions
Depth74 mm
Width110 mm
Height212 mm
Weight380 g