Motion Features
Product Reference Guide
287
Motion Features
Motionless Timeout
This setting specifies the amount of time that the reader takes to assume
that it is in a motionless condition. The range for this setting is from 500
msec to 25.5 seconds, in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0.5
= 0005 = 00, 5 = 050, 20 = 200, etc.
3. Go to
page 206 and scan the ENTER/EXIT PROGRAMMING MODE bar
code to enter Programming Mode.
4. Scan the bar code: SELECT MOT
I
ONLESS TIMEOUT SETTING.
5. Scan the appropriate three digits from the keypad in
Appendix D, Key-
pad
representing the duration which was determined in the steps
above. You will hear a two-beep indica
tion after the last character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See Table 47 for examples of how to set this
feature.
Table 47. Motionless Timeout Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
500ms 1 sec. 10 sec 9,900ms (9.9 sec.)
2
Divide by 100 (and pad
with leading zeroes to yield
two digits
)
005 010 100 250
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT MOTIONLESS TIMEOUT SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’, ‘0’ and ‘5’ ‘0’, ‘1’ and ‘0’ ‘1’, ‘0’, and ‘0’ ‘2’, ‘5’, and ‘0’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PM9500 and is the answer not in the manual?

Datalogic PowerScan PM9500 Specifications

General IconGeneral
TypeHandheld bar code reader
Wavelength680 nm
Sensor type-
Scanner type1D/2D
Tilt reading angle0 - 360 °
Pitch reading angle-40 - 40 °
Light levels (direct sunlight)0 - 100000 lx
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked Omnidirectional, MaxiCode, Micro QR Code, MicroPDF417, PDF417, QR Code
Wireless range150 m
Operating frequency910 MHz
Standard interfacesUSB, RS-232, RS-485
Connectivity technologyWireless
CertificationIEC 60825 Class 2 IEC 62471 Class 1 LED
Product colorBlack, Yellow
LED indicatorsYes
Protection featuresShock resistant
International Protection (IP) codeIP65
Sustainability certificatesRoHS
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Battery life10 h
Charging time4 h
Input voltage12 V
Battery capacity2150 mAh
Power consumption150 mA
Power source typeBattery
Cables includedNo
Weight and Dimensions IconWeight and Dimensions
Depth74 mm
Width110 mm
Height212 mm
Weight380 g