Enter/Exit Programming Mode
42
PowerScan™ PD9530/PBT9500/PM9500
Wedge Quiet Interval
Specifies amount of time to look for keyboard activity before scanner breaks
keyboard connection in order to transmit data to host. The selectable range
for this setting is 00 to 990 milliseconds (00-0x63 by 01) in increments of
ten milliseconds.
See page 264 in “References” for detailed information and
examples for setting this feature.
$CKBQI
Set Wedge Quiet Interval
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then
the bar code at left followed by the digits from
the Alphanumeric characters in
Appendix D,
Keypad
representing your desired character(s).
End by scanning the ENTER/EXIT bar code
agai
n.
Make a mistake? Scan the CANCEL bar code to
abor
t and not s
ave the entry string. You can
then start again at the beginning.
~
CANCEL
DEFAULT
0A = Quiet Interval is
100 milliseconds
Intercode Delay
Specifies the delay between labels transmitted to the host for this interface.
The selectable range for this feature is from 0 to 99 seconds.
See
page 266 in “References” for detailed information and examples for set-
ting this feature.
$CKBID
Set Intercode Delay
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then
the bar code at left followed by the digits from
the Alphanumeric characters in
Appendix D,
Keypad
representing your desired character(s).
End by scanning the ENTER/EXIT bar code
agai
n.
Make a mistake? Scan the CANCEL bar code to
abor
t and not s
ave the entry string. You can
then start again at the beginning.
~
CANCEL
DEFAULT
00 = No Wedge Intercode Delay

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PM9500 and is the answer not in the manual?

Datalogic PowerScan PM9500 Specifications

General IconGeneral
TypeHandheld bar code reader
Wavelength680 nm
Sensor type-
Scanner type1D/2D
Tilt reading angle0 - 360 °
Pitch reading angle-40 - 40 °
Light levels (direct sunlight)0 - 100000 lx
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked Omnidirectional, MaxiCode, Micro QR Code, MicroPDF417, PDF417, QR Code
Wireless range150 m
Operating frequency910 MHz
Standard interfacesUSB, RS-232, RS-485
Connectivity technologyWireless
CertificationIEC 60825 Class 2 IEC 62471 Class 1 LED
Product colorBlack, Yellow
LED indicatorsYes
Protection featuresShock resistant
International Protection (IP) codeIP65
Sustainability certificatesRoHS
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Battery life10 h
Charging time4 h
Input voltage12 V
Battery capacity2150 mAh
Power consumption150 mA
Power source typeBattery
Cables includedNo
Weight and Dimensions IconWeight and Dimensions
Depth74 mm
Width110 mm
Height212 mm
Weight380 g