Enter/Exit Programming Mode
Product Reference Guide
75
Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in
100 millisecond increments. See
page 283 in “References” for detailed
information on setting this feature.
Select Flash ON Time Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning
the ENTER
/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code t
o
abort
and not save the entry string. You can then start
again at the beginning.
10 = Flash is ON for 1 Second
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash
Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 sec-
onds), in 100 millisecond increments. See
page 284 in “References” for
detailed information on setting this feature.
Select Flash OFF Time Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning
the ENTER
/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to
abort
and not save the entry string. You can then start
again at the beginning.
06 = Flash is OFF for 600ms