Chapter 6 Control Mode of Operation ASDA-M
6-14
Revision December, 2014
6.2.6 Low-pass Filter
Related parameters:
P1-08 PFLT
Smooth Constant of Position
Command (Low-pass Filter)
Address: 0110H
0111H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 6.2.6
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
PTPR
Unit
10 ms
Range
0 ~ 1000
Data Size
16bit
Format
DEC
Example
11 = 110 ms
Settings
0: Disabled