Chapter 8 Parameters ASDA-M
8-248 Revision December, 2014
P7-xx PR Parameters (Please refer to Chapter 7 for detailed setting)
P7-00 PDEF50 PATH#50 Definition
Address: 0700H
0701H
Parameter
Attribute:
Parameter for individual axis
Related Section:
Section 7.10
Operational
Interface:
Panel / Software Communication
Default:
0x00000000
Control
Mode:
PR
Unit:
-
Range:
0x00000000 ~ 0xFFFFFFFF
Data Size:
32bit
Format:
HEX
Settings:
Please refer to the description of P6-02
NOTE
PATH (procedure)
P7-01 PDAT50 PATH#50 Data
Address: 0702H
0703H
Parameter
Attribute:
Parameter for individual axis
Related Section:
Section 7.10
Operational
Interface:
Panel / Software Communication
Default:
0
Control
Mode:
PR
Unit:
-
Range:
-2147483648 ~ +2147483647
Data Size:
32bit
Format:
DEC
Settings:
Please refer to the description of P6-03