H - 2 Activity Log & Transaction Messages
DigiGate-700
for Windows
®
This section describes the way that the DigiGate-700 for Windows program displays Activity
Messages to the user. The site activities are broken down into two categories. The first is tenant
activities which describe tenant movement and usage of the site or the operation of the system
hardware. These activities are listed in the Activity Log and on the Activity Log Report. The
second category is management or user activity which shows move in, move out, delinquents,
payments, and changes to data in a tenant or unit record. Management activities are shown in the
Transaction Log Report and entries will be made when the User initiates an action in the
DigiGate-
700 for Windows
program or when the Accounting program transfers information to the
DigiGate-
700 for Windows
database.
Introduction
Access Activities
1. Access Granted - A tenant entered a password at an entry device and was allowed to enter.
2. Delinquent - A tenant entered a password at an entry device and was denied access because they were
overdue in their account.
3. Bad Password - A password was entered at an entry device but was not found in the SysCon database.
4. Bad Keypad Zone - A tenant entered a password at an entry device and was denied access because they
were not authorized to use that specific entry device.
5. Bad Time Zone - A tenant entered a password at an entry device and was denied access because they were
not within the authorized hours to use that specific entry device.
6. Soft Antipassback - A tenant entered a password at an exit device and was allowed to exit but the Manager
was notified because the tenant had not used an entry device. (Tailgating)
7. Hard Antipassback - A tenant entered a password at an exit device and was not allowed to exit and the
Manager was notified because the tenant had not used an entry device. (Tailgating)
8. Not Found - When the DigiGate-700 for Windows program is not running, the System Controller stores
all activities in its memory. When the program is started it retrieves all activities from the SysCon and
stores them in the database. This message occurs when a code was entered and found valid in the System
Controller yet the unit was not found in the DigiGate-700 for Windows database on the PC. This can
signify a database error on the PC. Print and verify a tenant list.
Activity Log Messages
Misc. (SysCon) Activities
1. Cold Start - The System Controller has been reset, all memory on the board has been lost and you need to
perform a Set Controller and a Download All Units to complete the proper reset of the system.
2. System Reset - The System Controller has lost power for less than one minute. Data should be intact and
the gate should be working normally. This is a notification that a power fluctuation has occurred.
3. System Power Off - The System Controller has lost power for more than one minute. Data should be
intact and the gate should be working normally. This is a notification that a power failure has occurred.
The keypads will not work while the power is off, but should be OK when the power is back on.
4. System Power On - The System Controller has regained power after a System Power Off.