H - 3DigiGate-700
for Windows
®
- User’s Guide
DigiGate-700
for Windows
®
Time Activities
1. Time Zone Active - This indicates that the starting time of one of the time zones has passed and that the
input points will now operate for tenants in that time zone. The Time Zone name appears in the
Input
Point
column.
2. Time Zone Idle - This indicates that the ending time of one of the time zones has passed and that the input
points will not operate for tenants in that time zone. The Time Zone name appears in the
Input Point
column.
3. Timer Op Active - This indicates that the starting time of one of the timer operations has passed and that
the defined operation will be performed. An example of a timer operation is all tenants cleared from the
site at 11:59 P.M. or all vacant units are armed at 5:00 P.M.
4. Timer OP Idle - This indicates that the ending time of one of the timer operations has passed and that the
defined operation has been performed.
Board Activities
1. Board Online - During a
Set Controller
the board listed under
Input Point
initialized correctly. This
message applies to the Keypad board, Mux boards, or Graphics boards.
2. Board Offline - Communication to the board listed under
Input Point
has been lost. This could be due to
power failure or RS485 line problems. This message applies to the Keypad boards, Mux boards, or
Graphics boards.
3. Board AC Power Fail - The Keypad board, Mux board, Graphics board, or other RS485 device listed
under
Input Point
has lost its main power source and is running under backup power. This message
occurs only if the board has a battery backup.
4. Board AC Power Restored - The Keypad board, Mux board, Graphics board, or other RS485 device listed
under
Input Point
has regained its main power source and is no longer running under backup power. This
message occurs only if the board has a battery backup.
5. Board Battery Fail - The Keypad board, Mux board, Graphics board, or other RS485 device listed under
Input Point
has lost its backup power source. This message occurs only if the board has a battery backup.
You should contact your installer or our service department for a new battery.
6. Tamper Closed - This message only appears when the optional Tamper Switch has been installed on a Mux
box. The message indicates that the box is secure.
7. Tamper Open - When the optional Tamper Switch has been installed on a Mux box, this message indicates
that the box is not secure and has been opened. On a system that does not have the Tamper Switch
installed, this message will appear right after the Board Online message and has NO significant meaning.