4-15
CHAPTER 4 FINE-ADJUSTMENT AND OPTION SETTING
3.
Setting the Options
Press the option tab to enable the optional functions. Press the main menu tab to return to the main
menu.
3-1. Setting the Nipping Delay Time
You can specify the time from the moment a book block arrives at the nipper till when the nipping
operation starts. Note that the time should be less than the open time of the hot melt glue you use.
1.
Press or to change the nipping delay time.
Default setting: 0.0 sec. Setting range: 0.0 to 30.0 sec.
2.
Press the next button to display other option screen.
Example
10.0
5.0
30.0
Next Button
Nipping Delay Time
20.0
When binding a book block without a cover, if the nipping time is short, the booklet may
be discharged before the applied glue is dry and the glue may be adhered to the level
plate. Take enough nipping time when binding a book block without a cover.
3-2. Setting the Nipping Time
Nipping will be performed for the specified time. If the cover is not firmly adhered to the book block,
increase the nipping time.
1.
Press or to change the nipping time.
Default setting: 0.75 sec. Setting range: 0.0 to 5.0 sec.
When the nipping time is set to 0, nipping will not be performed.