158
Service codes
when the drive
units are engaged
("engaged" cali-
bration)
St1 | E 16
Cause: Push-pull calibration was interrupted: Quick-stop was activated by pressing
the torch trigger.
Remedy: Repeat push-pull calibration
St2 | E 7
Cause: "Push-pull calibration - open-circuit" has not been carried out
Remedy: Carry out "push-pull calibration - open-circuit"
St2 | E 8
Cause: At minimum wire feed speed, the wire-feed unit motor does not deliver any ac-
tual rotational speed value.
Remedy: Repeat the push-pull calibration. If the error message re-appears: Contact Af-
ter-Sales Service.
St2 | E 9
Cause: At minimum wire feed speed, the motor of the push-pull unit does not deliver
any actual rotational speed value.
Remedy: Repeat the push-pull calibration. If the error message re-appears: Contact Af-
ter-Sales Service.
St2 | E 10
Cause: At minimum wire feed speed, the motor current of the wire-feed unit motor is
outside the permitted range. Possible reasons are disengaged wire-feed unit
motors or wire feed problems.
Remedy: Engage the drive units of both wire-feed unit motors, arrange the hosepack in
as straight a line as possible; check the inner liner for kinks or soiling; check
the contact pressure on the 2-roller or 4-roller drive of the push-pull unit. Re-
peat the push-pull calibration. If the error message re-appears: Contact After-
Sales Service.
St2 | E 11
Cause: At minimum wire feed speed, the motor current of the push-pull unit is outside
the permitted range. Possible reasons are disengaged wire-feed unit motors
or wire feed problems.
Remedy: Engage the drive units of both wire-feed unit motors, arrange the hosepack in
as straight a line as possible; check the inner liner for kinks or soiling; check
the contact pressure on the 2-roller or 4-roller drive of the push-pull unit. Re-
peat the push-pull calibration. If the error message re-appears: Contact After-
Sales Service.
St2 | E 12
Cause: At maximum wire feed speed, the wire-feed motor does not deliver any actual
rotational speed value.
Remedy: Repeat the push-pull calibration. If the error message re-appears: Contact Af-
ter-Sales Service.
St2 | E 13
Cause: At maximum wire feed speed, the motor of the push-pull unit does not deliver
any actual rotational speed value.
Remedy: Repeat the push-pull calibration. If the error message re-appears: Contact Af-
ter-Sales Service (faulty actual-value pick-up)

Table of Contents

Other manuals for Fronius CMT 4000 Advanced

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius CMT 4000 Advanced and is the answer not in the manual?

Fronius CMT 4000 Advanced Specifications

General IconGeneral
BrandFronius
ModelCMT 4000 Advanced
CategoryAC Power Distribution
LanguageEnglish

Related product manuals