19
EN
Safety measures
in normal opera-
tion
When transporting the device, observe the relevant national and local guide-
lines and accident prevention regulations. This applies especially to guidelines
regarding the risks arising during transportation.
Before transporting the device, allow coolant to drain completely and detach
the following components:
- Wire-feed unit
- Wirespool
- Shielding gas cylinder
After transporting the device, and before commissioning, you MUST carry out
a visual inspection to check whether it has been damaged in any way. Any
damage must be repaired by trained service technicians before commission-
ing takes place.
Only operate the device when all protection devices are fully functional. If the
protection devices are not fully functional, there is a risk of
- injury or death to the operator or a third party,
- damage to the device and other material assets belonging to the operator,
- inefficient operation of the device.
Any safety devices that are not functioning properly must be repaired before
switching on the device.
Never bypass or disable protection devices.
Before switching on the device, ensure that no one is likely to be endangered.
- Check the device at least once a week for obvious damage and proper
functioning of safety devices.
- Always fasten the shielding gas cylinder securely and remove it before-
hand if the device is to be transported by crane.
- Only the manufacturer's original coolant is suitable for use with our devic-
es due to its properties (electrical conductivity, frost protection, material
compatibility, flammability, etc.)
- Only use suitable original coolant from the manufacturer.
- Do not mix the manufacturer's original coolant with other coolants.
- If damage results from using a different coolant, the manufacturer accepts
no liability. In addition, no warranty claims will be entertained.
- The coolant can ignite under certain conditions. Transport the coolant
only in its original, sealed containers and keep well away from any sourc-
es of ignition
- Used coolant must be disposed of properly in accordance with the rele-
vant national and international regulations. A safety data sheet may be
obtained from your service centre or downloaded from the manufacturer's
website.
- Check the coolant level before you start to weld while the system is still
cool.

Table of Contents

Other manuals for Fronius CMT 4000 Advanced

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius CMT 4000 Advanced and is the answer not in the manual?

Fronius CMT 4000 Advanced Specifications

General IconGeneral
BrandFronius
ModelCMT 4000 Advanced
CategoryAC Power Distribution
LanguageEnglish

Related product manuals