Troubleshooting
General The digital power sources are equipped with an intelligent safety system. This means that
apart from the fuse for the coolant pump, it has been possible to dispense with melting-type
fuses entirely. After a possible malfunction or error has been remedied, the power source
can be put back into normal operation again without any fuses having to be replaced.
Safety
Displayed service
codes
If any error message that is not described here appears on the displays, then the fault can
only be fixed by a service technician. Make a note of the error message shown in the dis-
play and of the serial number and configuration of the power source, and contact our After-
Sales Service team with a detailed description of the error.
-St | oP-
Where the power source is being operated with a robot interface or a field bus
Cause: Robot not ready
Remedy: Initialise "Robot ready" signal, initialise "Source error reset" signal ("Source
error reset" only available in conjunction with ROB 5000 and field bus coupler
for robot control)
dsP | A21
Can only occur when power sources are being operated in parallel or in Twin mode
Cause: The power source is configured for either parallel operation (setup parameter
P-C is set to “ON”) or for TimeTwin Digital (setup parameter T-C is set to
“ON”). However, the LHSB link has been disconnected or has become faulty
while the power source was switched on.
Remedy: Reset the service code: Switch the power source off and back on again. If
necessary, restore or repair the LHSB link.
dSP | Axx
Cause: Fault in the central control and regulation unit
Remedy: Contact After-Sales Service
dSP | Cxx
Cause: Fault in the central control and regulation unit
Remedy: Contact After-Sales Service
WARNING! An electric shock can be fatal. Before opening the device
- Turn the mains switch to the "O" position
- Unplug the machine from the mains
- Prevent it from being switched on again
- Using a suitable measuring instrument, check to make sure that electrically
charged components (e.g. capacitors) have discharged
CAUTION! Inadequate PE conductor connections can cause serious injury and
damage. The housing screws provide a suitable PE conductor connection for
earthing (grounding) the housing and must NOT be replaced by any other screws
which do not provide a reliable PE conductor connection.