79
EN
Start-up
Safety
Remarks on the
cooling unit
We recommend using an FK 4000 R cooling unit for the following applications and situa-
tions:
- TS 4000 / 5000, TPS 3200 / 4000 / 5000 power sources
- JobMaster welding torch
- Push-pull welding torch
- Robot welding
- Hosepacks over 5 m long
- MIG/MAG pulse synergic welding
- In general, where welding is performed in higher power ranges
The cooling unit is powered from the power source. The cooling unit is ready for operation
when the mains switch of the power source is in the - I - position.
More information on the cooling unit can be found in the operating instructions for the cool-
ing unit.
Information on
system compo-
nents
The steps and activities described below include references to various system compo-
nents, including:
- Trolleys
- Cooling units
- Wire-feed unit holders
- Wire-feed units
- Interconnecting hosepacks
- Welding torches
-etc.
For more detailed information about installing and connecting the system components,
please refer to the appropriate operating instructions.
Overview "Commissioning" is composed of the following sections:
- Commissioning the TPS 2700
- Commissioning the TS 4000/5000, TPS 3200/4000/5000
- Commissioning the CMT 4000 Advanced
WARNING! An electric shock can be fatal. If the power source is connected to the
mains electricity supply during installation, there is a high risk of very serious in-
jury and damage. Before carrying out any work on the device make sure that:
- the power source mains switch is in the "O" position
- the power source is unplugged from the mains