March 2008
5-2 Clearing Data
Clearing Totalized Data The TOTAL submenu permits the user to reset volumetric totals to zero
and to reset the stopwatch totalizer. Press the appropriate side of the
[SCREEN] key to activate the desired pane of the display screen, and
complete the following steps:
1. To access the Clear Menu, press the
[CLR] key.
a. If you have activated the security feature (see Chapter 1,
Programming Site Data, page 1-63 for details), enter the
assigned password and press
[ENT].
2. Press
[F1] = TOTAL.
3. Press
[F1] to abort the procedure or press [F2] to clear all
volumetric totals and reset the stopwatch totalizer. In either case,
the initial Clear Menu prompt returns.
Deleting Site Files Use the SITE submenu to clear site files from the DF868’s memory.
Use the
[SCREEN] key to activate the desired display pane, and refer to
the menu map in Appendix A, page A-8 while completing the
following steps:
1. To access the Clear Menu, press the
[CLR] key.
a. If you have activated the security feature (see Chapter 1,
Programming Site Data, page 1-63 for details), enter the
assigned password and press
[ENT].
2. Press
[F2] = SITE.
3. At the Site Name prompt, use the [←], [→] and
[F1]-[F4] keys to
select a site file for deletion. To leave the
SITE submenu, press the
[EXIT] key.
Note: At the
SITE NAME prompt, the option bar shows the names of
all site files currently stored in memory.
4. Press
[F1] to abort the procedure, or press [F2] to Clear the
specified site file. If any site files remain in memory, the Site
Name prompt repeat
s.
When all of the stored site files have been cleared or the [EXIT] key has
been pressed at the
SITE NAME prompt, the programming sequence
resumes at this point.