107
4 = Auto arming on Wednesday
5 = Auto arming on Thursday
6 = Auto arming on Friday
7 = Auto arming on Saturday
8 = Disable retry timer
Communicator codes for slow speed formats only
Note: Locations 56-83 are only used when reporting events to a pager, or when using a slow format such as 4+2.
When using Contact ID or SIA, there is no need to program these locations.
LOCATION 56 - RESTORE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (4 segments,
numerical data)
Location 56 contains the event code for a zone “Restore” for a 4+2 and 3+1 format. For a 4+2
format, the digit programmed in this location will be sent as the tens digit of the restore event code.
The zone ID will always be reported as the ones digit of the zone number (e.g. zone 12 = 2,
zone 44 = 4).
This location contains 4 segments. Any segment left as “0” will follow the segment 1 selection.
Segment 1
Partition 1 “Restore Code”
Segment 2
Partition 2 “Restore Code”
Segment 3
Partition 3 “Restore Code”
Segment 4
Partition 4 “Restore Code”
LOCATION 57 - BYPASS COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (4 segments,
numerical data)
Location 57 contains the event code for a zone “Bypass” with a 4+2 and 3+1 format. For a 4+2
format, the digit programmed in this location will be sent as the tens digit of the bypass event code.
The zone ID will always be reported as the ones digit of the zone number (e.g. zone 12 = 2, zone 44
= 4).
This location contains 4 segments. Any segment left as “0” will follow the segment 1 selection.
Segment 1
Partition 1 “Bypass Code”
Segment 2
Partition 2 “Bypass Code”
Segment 3
Partition 3 “Bypass Code”
Segment 4
Partition 4 “Bypass Code”
LOCATION 58 - TAMPER COMMUNICATOR CODE, SLOW SPEED FORMATS (4 segments,
numerical data)
Location 58 contains the event code for a zone “Tamper” with a 4+2 and 3+1 format. For a 4+2
format, the digit programmed in this location will be sent as the tens digit of the tamper event code.
The zone ID will always be reported as the ones digit of the zone number (e.g. zone 12 = 2, zone 44
= 4).
This location contains 4 segments. Any segment left as “0” will follow the segment 1 selection.