connection type and must be done before the phone number and IP address can be
programmed.
2. Navigate with the ½¾ keys to NX-7002 Module>Up/Download>IP Address and press
OK.
3. Press #¾ to clear the current value.
4. Enter the IP Address and press OK.
5. Navigate with the ½¾ keys to NX-7002 Module>Options>Network>Port Numbers>U/D
Port and press OK
6. Select the U/D port and press OK.
Reporting summary
The following table summarises the programming information required for different types of
reporting.
Table 21. Reporting Summary
Report type
Information
required
Menu Option
Contact ID over SMS Phone Number Select NX-7002 Module>Reporting>SMS Reporting>Receiver n>Phone
number.
Account code Select NX-7002 Module>Reporting>SMS Reporting>Receiver n>Account
Code.
Protocol Select NX-7002 Module>Reporting>SMS Reporting>Receiver
n>Protocol>Contact ID.
Destination Select NX-7002 Module>Reporting>Report Control>Report
n>Destination>SMS1 or SMS 2.
SMS Service
Centre
Select NX-7002 Module>Options>GSM>SMS Service Center Address.
SIA over SMS Phone Number Select NX-7002 Module>Reporting>SMS Reporting>Receiver n>Phone
number.
Account code Select NX-7002 Module>Reporting>SMS Reporting>Receiver n>Account
Code.
Protocol Select NX-7002 Module>Reporting>SMS Reporting>Receiver
n>Protocol.
Select SIA Separate, SIA Combined or SIA Partition Modified.
Destination Select NX-7002 Module>Reporting>Report Control>Report
n>Destination>SMS1 or SMS 2.
SMS Service
Centre
Select NX-7002 Module>Options>GSM>SMS Service Center Address.
XSIA over SMS Phone Number Select NX-7002 Module>Reporting>SMS Reporting>Receiver n>Phone
number.
Account code Select NX-7002 Module>Reporting>SMS Reporting>Receiver n>Account
Code.
Enable XSIA Select NX-7002 Module>Reporting>XSIA