NX-10 Installers manual
205
01/04 05:57 Close
[Arm] P1 User 1
01/04 05:57 Close
[Arm] P2 User 1
Table 30. HomeText example
Part of Message Description
GE[Security] Site address
01/04 05:57 Date and time
Close [Arm] Action reported
P1 Partition number
User 1 User name
Glossary
Term Definition
A
Account Code
A Reporting setting that configures the SIA or Contact ID account number for the selected report
receiver. SIA account numbers are 6 digits long. Contact ID account numbers are 4 digits long. The
letters A, B, C, D, E and F can be included in account codes.
Alarm Restores
A Reporting setting that sends a report to the selected report control when the alarm has been
restored after an alarm.
Alarms A Reporting setting that sends a report to the selected report control when an alarm occurs.
All abort
A Control Panel menu entry that cancels all pending reports if the system is disarmed during
reporting.
Allow Calls From
An Up/download setting that answers calls from a known phone number only. To enable this setting,
you must enable Remote Initiated and program the phone number of the PC in Up/Download>Phone
Number.
Any Phone Access
A Reporting menu entry that lists all the users with rights to send HomeText commands from the
phone unknown to the system.
Note: Sending a HomeText message from the unknown phone requires adding the phone number
registered for the user and the user password at the beginning of the command. They are used by
the system to confirm the user's identity. For example, type 32444123456 44aa44 status to send a
status command, where 32444123456 is your telephone number registered in the system, and
44aa44 is your password.
Application An Options menu entry that groups application related status messages.
Arm/Disarm/Alarm A Reporting menu entry that groups the events that are reported to the selected report control.
Auto U/D at Test
Time
An Up/download setting that configures the NX-7002 to automatically dial the PC to initiate an
upload/download session after an autotest. You must program the autotest on the control panel.