NX-10 Installers manual
53
The control panel includes up to 2 programmable on-board auxiliary outputs. To program on-board
outputs, select Installer Menu>Control Panel>Outputs.
Configuring an output
You can change the characteristics of each output. You must specify the events and/or partitions that
activate an output and the length of time for which the output is activated. The events are grouped in
the programming tree. A full list of all possible selectable events can be found in the Table 12,
Control panel output events. The following example configures ou
tput 1 to activate for 15 minutes
when a burglary alarm occurs.
1. Navigate with the ½¾ keys to Control Panel>Outputs>Prog Outputs>Output 1 and
press OK.
2. Scroll to Event>Alarms>Burglary Alarm and press OK.
3. The keypad beeps once to confirm the change and returns to Alarms.
4. Scroll to Time Unit>Minutes and press OK.
5. The keypad beeps once to confirm the change and returns to Time Unit.
6. Scroll to Time and press OK.
7. Select 15 min. and press OK to accept the changes.
8. The keypad beeps once to confirm the change and returns to Time.
Table 12. Control panel output events
Data Event Data Event
0 Burglary alarm 30 Open period
1 Fire alarm 31 Closed period
2 24 hour alarm 32 Listen-in
3 Trouble alarm 33 Line seizure
4 Tamper alarm 34 Reserved
5 Yelping siren 35 Fail to communicate
6 Steady siren 36 Telephone line fault
7 Any siren 37 Program mode
8 Any bypass 38 Download in process
9 AC fail 39 Reserved
10 Low battery 40 Short circuit (overcurrent on 12 V DC)
11 Duress 41 Box tamper
12 Aux 1 keypad (fire alarm) 42 Siren tamper
13 Aux 2 keypad (medical alarm) 43 Any open
14 Panic keypad 44 Any short
15 Keypad tamper 45 Any fault (open/short on non-fire zone)
16 Automatic test 46 Any alarm
17 Alarm memory (solid) 47 Audible keypad
18 Entry 48 Code entry (see note below)
19 Exit 49 Keyfob function 1
20 Entry or exit 50 Keyfob function 2
21 Armed state 51 Always ON
22 Disarmed state 52 Autoarm warning time
23 Ready 53 Any siren when in away mode
24 Not ready 54 Progress of entry/exit (follows keypad
buzzer)