LOGI CONTROL. Advanced mode 33
Cod. 523340
Rev. 10/1016
6.5. Modifying a program
6.5.1. Programming vectors
See the definition of the functions and values programmable in each phase in the following sections.
PHASE
EXECUTION
LEVEL
TEMP.
DISP.
ROTATION
ROTATION
TIME
COOL
DOWN
PAUSE
EXTRACT
EXTRACT
TIME
Ph
L
C / F
d
r
rt
c
rh
E
Et
1
Y / N
1…4
0 ... 90
32 ... 194
0, 1...4
1...3
1...12
n.p.
n.p.
0 / 1
n.p.
2
Y / N
1…4
0 ... 90
32 ... 194
0, 1...4
1...3
1...12
n.p.
n.p.
0 / 1
n.p.
3
Y / N
1…4
0 ... 90
32 ... 194
0, 1...4
1...3
1...12
n.p.
n.p.
0...3
n.p. 2...4
4
Y
1…4
0 ... 90
32 ... 194
0, 1...4
1...3
1...20
0 / 1
n.p.
0...2
n.p. 2...4
5
Y / N
1…4
0 ... 60
32 ... 140
0, 1...4
1...3
1...12
n.p.
n.p.
1...3
n.p. 2...4
6
Y / N
1…4
n.p.
0, 1...4
1...3
1...12
n.p.
n.p.
1...3
n.p. 2...4
7
Y / N
1…4
n.p.
0, 1...4
1...3
1...12
n.p.
n.p.
1...3
n.p. 2...4
8
Y / N
1…4
n.p.
0, 1...4
1...3
1...12
n.p.
n.p.
1
n.p.
9
Y
1…4
0 ... 60
32 ... 140
0, 1...4
1...3
1...12
n.p.
0 / 1
1...6
n.p. 2...9
Note: (UK setting only). Program 3 cannot be modified.
6.5.2. Definition of phases
PHASES
DEFINITION
1, 2, 3
Soaking and pre-washes. Optional execution phase.
4
Washing. Obligatory execution phase.
5
First Rinse. Optional execution phase.
6 - 8
Second, third and fourth rinses. Optional execution phase.
9
Final Rinse. Obligatory execution phase.

Table of Contents

Other manuals for GIRBAU LOGI CONTROL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GIRBAU LOGI CONTROL and is the answer not in the manual?

GIRBAU LOGI CONTROL Specifications

General IconGeneral
BrandGIRBAU
ModelLOGI CONTROL
CategoryController
LanguageEnglish

Related product manuals