Troubleshooting 75
Cod. 523340
Rev. 10/1016
9.5. System alarms
The safety of the washing machine in use requires the machine to monitor itself closely for any possible
anomalies. These anomalies are reported in the form of alarms.
The ALM message will appear on the washing machine’s display alternating with the specific alarm report.
DISPLAY REPORT
LIKELY CAUSE
PROCEDURE
ALM/A-*
Faulty water inlet
Check water entry pressure.
Check the manual water inlet valves.
Check the status of the filters in the solenoid
valves. (Refer to section 10: Maintenance)
Defect in the solenoid valves
Defect in the level control system
Contact Authorised Technical Services.
ALM/E
Machines with pump drain: obstruction of the
draining pump
Contact Authorised Technical Services.
Anomaly in the drain system
Error in drain configuration
Check the status of the washing bath’s output
hoses.
Contact Authorised Technical Services.
ALM/HOT
Inadequate stop of the washing machine with
bath at high temperature
Excessive temperature when machine is
stopped
Anomaly in the heating system
Close the door of the washing machine to allow
opening of cold water valve.
Press START/STOP key to drain the bath and
access the door opening.
Repeat this operation until the alarm report
disappears.
If the alarm report does not disappear after five
attempts, disconnect the general power supply
and close the water inlet manual valves.
Contact AUTHORISED TECHNICAL
SERVICES.
ALM/L
Leakage in the solenoid valve
Bath level with machine idle
Close manual water inlet valves.
Contact AUTHORISED TECHNICAL
SERVICES.
ALM/SL
Bath level exceeded
Close manual water inlet valves.
Contact AUTHORISED TECHNICAL
SERVICES.
ALM/C
Defect in the temperature probe
Error in the heating configuration
Defect in the heating circuit
Contact AUTHORISED TECHNICAL
SERVICES.
ALM/Prob
Defect in the temperature probe
Contact AUTHORISED TECHNICAL
SERVICES.
ALM/BAL
Defect in the unbalance control switch
Contact AUTHORISED TECHNICAL
SERVICES.
ALM/VAR*
Disconnection of the motor’s thermal protection
Alarm set off by the inverter
Contact AUTHORISED TECHNICAL
SERVICES.
ALM door
Faulty door lock
Contact AUTHORISED TECHNICAL
SERVICES.
Hot
Interruption of the program using the
START/STOP key with the bath at high
temperature
The washing machine will automatically accept
cold water and will not allow the door unlock.
When the bath temperature is below 45 ºC
(133 ºF) the bath will drain and the safety door
lock will be released.
door
Door badly closed
Open and close the door.

Table of Contents

Other manuals for GIRBAU LOGI CONTROL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GIRBAU LOGI CONTROL and is the answer not in the manual?

GIRBAU LOGI CONTROL Specifications

General IconGeneral
BrandGIRBAU
ModelLOGI CONTROL
CategoryController
LanguageEnglish

Related product manuals