GR SG9013088000000000
CP2000 Center
confidential
B.1.9
1.8 Switching the double sheet detector in the pull lay on or off (option)
Basic adjustment / feeder
12345
Job
Name
Basic
adjustment
1
2
3
4
6
5
Fig. 9 Switching the double sheet detector in the pull lay on/off
The Basic adjustments/Feeder menu enables you
to switch on or off the double sheet detector in the
pull lay (option).
1. In the header, press the button
Malfunction
(Fig. 9/1). The Malfunction menu appears.
2. Press the
Service
button (Fig. 9/2). The Ser-
vice menu appears.
3. Press the
Basic settings
button (Fig. 9/3). The
menu Basic settings/Start-up warning signal
appears.
4. Press the
Feeder
button (Fig. 9/4). The Basic
adjustments/Feeder menu (Fig. 9) appears.
5. To switch on or off the double sheet detector in
the pull lay: Press the button (Fig. 9/5). The but-
ton is highlighted when the double sheet detec-
tor is switched on.
If your press is equipped with a double sheet detec-
tor in the pull lay and an ultrasonic double sheet de-
tector, you may:
D switch on both double sheet detectors
D switch off the double sheet detector in the pull
lay or the ultrasonic double sheet detector.
One of the two double sheet detectors always re-
mains ON.
UTKSG9013008000000000007