Remote Reset [67] Galaxy Flex Installer Manual
176
Remote Reset [67]
Use this option to perform an engineer reset authorized by the Alarm Receiving Centre
(ARC). In the event of an alarm that requires an engineer reset, the keypad displays a
number, which, when quoted to the ARC is decoded and exchanged for a new number.
When this new number is entered it resets the panel. Entering the engineer code also resets
the panel.
Note: The alarm conditions that require to be reset remotely must have the appropriate
System Reset, Tamper Reset or PA Reset parameters programmed for engineer reset
(type 7).
Each alarm activation generates a random number, therefore the number required to reset the
panel changes each activation. As ARCs have different decoding equipment, the appropriate
reset system must be selected from the following Remote Mode options:
0=OFF (default)
1=SMS – Southern Monitoring Service (4 digits)
2=Technistore – requires a three-digit local modifier (000 to 255) to be assigned
Note: Assign the local modifier for the Technistore reset mode after discussion with the
ARC.

Table of Contents

Other manuals for Honeywell Galaxy Flex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex and is the answer not in the manual?

Honeywell Galaxy Flex Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex
CategoryControl Panel
LanguageEnglish

Related product manuals