42
When you access the event log, the most recent event is displayed. Use A or B to scroll
through the events. Hold down either key to scroll quickly through the dates.
The event log is wrapped round from beginning to end. The message START or END is
briefly displayed when the wrap-around is passed through.
The following information is detailed in the event log:
Time of event.
Date the event occurred.
Event - information about the type of event that occurred. Certain events are displayed
with a + (indicating that the event started or was activated) or (indicating that the
event ended or was terminated) symbol.
User - alternates between the name and number of the user who initiated the event. If
the event is not associated with a user code, for example, an alarm activation or a final
zone closing, then no user information is displayed.
Press # while viewing the log to see additional information about certain event types:
User events reveal the keypad, user type and user group involved in the event.
Alarm events reveal the zone descriptor, if programmed.
Walk tested RF zones reveal the measured signal strength of each RF device.
REM CALL event displays the Remote Station ID for the Remote Servicing Software
which has made the connection with the panel.
Notes:
1. Where two identical events occur within 1 second, only one is logged.
2. Only the first occurrences of high resistance and low resistance events on each day are
logged. Subsequent activations are ignored until midnight of the same day. This is to
prevent the log from being filled with high and low resistance activations from a faulty
zone.
You can print the event log while accessing the Display Log option. Press
while
displaying an event to start the printout. All events from the displayed event to the most
recent event are printed. If required, press esc to abort a print out.
Note: A printer must be connected to the panel via a printer interface module.
System [23]
Use this option to display an overview of the system configuration. You can scroll through
the items shown below, which are displayed using both lines on the keypad screen.
10:24 SUN 01 JAN
K10 L7
K = keypad
user type (user level)
keypad address
AB line

Table of Contents

Other manuals for Honeywell Galaxy Flex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex and is the answer not in the manual?

Honeywell Galaxy Flex Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex
CategoryControl Panel
LanguageEnglish

Related product manuals