Galaxy Flex Installer Manual View zone information
25
Section 2: Commissioning and
handover
View zone information
Display zones (21 ent). View information about any selected zone.
Walk test
1. Select Test All Zones (31 ent 2 ent 2 ent 1) to perform an audible test. Alternatively,
to perform a silent test, press 31 ent 2 ent 1 ent 1.
It is possible to walk test selected zones only. Refer to Walk Test [31].
2. Activate each zone in turn.
Note: If you do not activate any zone for 20 minutes the test will stop automatically.
3. To end the test, press esc.
Walk test results
To view the results of your walk test, select Display Log (22 ent).
Test outputs
Outputs are tested by function, for example Bells or Strobe.
1. Select Outputs (32 ent). 01=Bells is displayed on the keypad.
2. Press A or B to move to the output you wish to test, or type its number.
3. Press ent to test the selected output device.
4. Press ent to stop the test.
5. Repeat steps 2 to 4 to select and test other outputs.
6. Press esc to exit the Test Output function.
Diagnostic test (optional)
Check the Latest (61 ent 1 ent) and Historical (61 ent 2 ent) status of:
Modules
PSU
baseline record