109
Page 109
Mini-AT User Guide
Item
No. Item Name Description
————————————————————————————————————————
137 PCOR XDCR RANGE The upper PCor pressure range limit, automatically scaled to the
pressure units selected at item 087. If PSI is the selected pressure
units, then item 137 will be the same as item 025. Note; the value
at item 137 may be manually edited to a rounded-off number, if
desired.
Default = 100.00
138 PCOR TRANSDUCER SER# Serial number of the PCor pressure transducer (printed on the
transducer label), manually inserted at the factory. Note: forcing
Factory Defaults will
not change the value of this item.
Default = 00000000
139 SERIAL LINK CODE Code (0 - 2) to define the behavior of the instrument’s RS-232
serial data transfer with Mini-AT LINK and other 3rd-party
software
Select: 0 - Two Way (Read and Write) Default
1 - Read Only
2 - Disabled (Will not Read or Write)
140 ENERGY The totalized gas energy, equivalent to the totalized corrected
volume (item 000) multiplied by the Gas Energy Value (item 142)
and updated every correction cycle.
Default = 00000000
141 ENERGY UNIT CODE The code (0 - 5) that selects the unit of measure for Energy (140).
Select: 0 - THERMS ---Default 3 - GJOULES
1 - DKTHERMS 4 - KILOCAL
2 - MJOULES 5 - KILOWATTHR
142 GAS ENERGY VALUE User-provided value to indicate the amount of energy contained in
each volumetric unit of corrected volume. This value is a
multiplier used to calculate Energy at item 140. The nominal Gas
Energy Values for the various Energy Units (item 141) are listed
below:
THERMS - 1000 BTU per CuFt of gas Default
DKTHERMS - 1000 BTU per CuFt of gas
MJOULES - 37259.00 Kilojoules per m3 of gas
GJOULES - 37259.00 Kilojoules per m3 of gas
KILOCAL - 8905.00 Kilocalories per m3 of gas
KILOWATTHR - 10349.73 Watt/Hr per m3 of gas