Special physical functions
Menu 117, triggered by using MENU(117) in ALG mode, or 117 ` MENU
in RPN mode, produces the following menu (labels listed in the display by using
‚˜):
The functions include:
ZFACTOR: gas compressibility Z factor function
FANNING: Fanning friction factor for fluid flow
DARCY: Darcy-Weisbach friction factor for fluid flow
F0
λ: Black body emissive power function
SIDENS: Silicon intrinsic density
TDELTA: Temperature delta function
In the second page of this menu (press L) we find the following items:
In this menu page, there is one function (TINC) and a number of units described
in an earlier section on units (see above). The function of interest is:
TINC: temperature increment command
Out of all the functions available in this MENU (UTILITY menu), namely,
ZFACTOR, FANNING, DARCY, F0
λ, SIDENS, TDELTA, and TINC, functions
FANNING and DARCY are described in Chapter 6 in the context of solving
equations for pipeline flow. The remaining functions are described following.
Function ZFACTOR
Function ZFACTOR calculates the gas compressibility correction factor for
nonideal behavior of hydrocarbon gas. The function is called by using

Table of Contents

Other manuals for HP 50G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 50G and is the answer not in the manual?

HP 50G Specifications

General IconGeneral
Digits33 digits
Battery typeCR2032
TypeScientific
Form factorPocket
Weight and Dimensions IconWeight and Dimensions
Weight220 g
Dimensions (WxDxH)87 x 184 x 23.5 mm

Related product manuals