Do you have a question about the HP MSR1003-8S and is the answer not in the manual?
Brand | HP |
---|---|
Model | MSR1003-8S |
Category | Network Router |
Language | English |
Enable or disable debugging for specific modules or all debugging functions.
Display currently enabled debugging functions.
Determine IP address reachability and display statistics.
Trace the path IPv6 packets traverse from source to destination.
Configure and manage NQA client operations.
Set advantage factor for MOS and ICPIF calculation in voice operations.
Configure the codec type for a voice operation.
Configure the destination IPv6 address for an NQA operation.
Configure the destination port number for an NQA operation.
Display current monitoring results of reaction entries.
Display the most recent result of a specified NQA operation.
Specify the interval at which an NQA operation repeats.
Set the lifetime of history records for an NQA operation.
Set the maximum number of history records that can be saved for an NQA operation.
Set the data transmission mode for FTP operation.
Specify the next hop IPv6 address for the ICMP echo operation.
Enable the NQA client.
Configure scheduling parameters for an NQA operation.
Specify the operation type for the HTTP operation.
Specify the output interface for probe packets.
Configure the interval for sending packets in the probe.
Set the number of packets sent per probe for UDP jitter, path jitter, or voice.
Set the probe timeout time.
Configure a reaction entry for monitoring the one-way delay.
Configure a reaction entry for monitoring the ICPIF value in the voice operation.
Configure a reaction entry for monitoring packet loss in UDP jitter or voice operation.
Configure a reaction entry for monitoring the probe failures of the operation.
Configure a reaction entry for monitoring packet round-trip time.
Enable routing table bypass function for direct destination connectivity test.
Configure the source IP address for probe packets.
Configure the source IPv6 address for probe packets.
Set the interval for collecting statistics for an NQA operation.
Perform path jitter operation only on the destination address.
Set the maximum number of hops that probe packets can traverse.
Specify FTP or HTTP login username.
Apply the operation to a VPN.
Display information about all IPv6 NTP associations.
Display information about all IPv4 NTP associations.
Display NTP service status.
Configure access-control right for peer devices to access NTP services.
Set an NTP authentication key.
Configure device to operate in NTP broadcast server mode.
Enable the NTP service.
Configure access-control right for peer devices to access IPv6 NTP services.
Enable an interface to process IPv6 NTP messages.
Configure device to operate in IPv6 NTP multicast server mode.
Specify an IPv6 symmetric-passive peer for the device.
Set the maximum number of dynamic NTP sessions allowed locally.
Configure device to operate in NTP multicast server mode.
Specify created authentication key as a trusted key.
Specify a symmetric-passive peer for the device.
Display information about all IPv6 SNTP associations.
Display information about all IPv4 SNTP associations.
Enable SNTP authentication.
Enable the SNTP service.
Specify the created authentication key as a trusted key.
Enable SNTP authentication.
Apply a PoE profile to a power interface (PI).
Apply a PoE profile to PIs.
Display general PSE information, including ID, slot number, and status of PSEs.
Display power information for PIs on a PSE.
Display power usage statistics for PoE power supplies and PSEs.
Display the PoE status of all PIs on a PSE.
Configure the maximum power for a PSE.
Configure a description for the PD that connects to a PI.
Configure a power supply priority for a PI.
Enable PSE power management.
Create a PoE profile and enter PoE profile view.
Display information about the PoE profile on a PI.
Enable PoE on a PI.
Enable a PSE to detect nonstandard PDs.
Display SNMPv1 or SNMPv2c community information.
Display an SNMP context.
Display SNMP group information, including group name, security model, MIB view, and storage-type.
Display SNMP MIB node information.
Display remote SNMP engine IDs configured using the snmp-agent remote command.
Create an SNMP group and specify its access right.
Configure SNMP agent to send extended linkUp/linkDown notifications.
Configure the lifetime of notifications in the SNMP notification queue.
Set the SNMP notification queue size.
Add a user to an SNMPv3 group or create an SNMPv3 user.
Display entries in the RMON alarm table.
Display RMON event entries.
Display event log entries.
Display entries in the private RMON alarm table.
Create an entry in the RMON alarm table.
Set an action for an event.
Specify a Boolean comparison type.
Configure a context for the set action.
Set a delta falling threshold.
Specify a delta rising threshold.
Configure a description for a trigger.
Display information about an event and the event action.
Display information about object lists.
Display information about a trigger and the trigger test.
Specify an event for a Boolean test.
Specify an event for an existence test.
Set a sampling interval.
Specify an object list for a trigger-Boolean test.
Specify an object list for a trigger-threshold test.
Specify a notification OID.
Specify a MIB object for trigger sampling.
Trigger an event for the first Boolean sampling.
Create an event and enter event view.
Specify the maximum number of sampling instances.
Create a trigger and enter trigger view.
Specify an existence test type for the first sampling.
Specify a trigger test type.
Specify an existence test type.
Set a reference value for a Boolean test.
Enable the context of an object to be wildcarded.
Enable a MIB object OID to be wildcarded.
Enable NETCONF over SOAP over HTTP.
Enable NETCONF over SOAP over HTTPS.
Enable NETCONF over SSH.
Enter XML view to use NETCONF messages for configuration or data retrieval.
Enter CWMP view.
Configure password for authentication to the default ACS URL.
Specify a default ACS URL.
Configure password for authentication to the preferred ACS URL.
Configure username for authentication to the preferred ACS URL.
Configure max attempts for a failed CWMP connection retry.
Configure the periodic Inform interval.
Schedule a connection initiation for the CPE to connect to the ACS.
Configure the provision code of the CPE.
Configure username for the CPE to authenticate the ACS.
Enable CWMP.
Display CWMP state information.
Add a CLI action to a monitor policy.
Add a reboot action to a monitor policy.
Add an active/standby switchover action to a monitor policy.
Enable a CLI-defined monitor policy.
Display monitor policies.
Configure a hotplug event for a CLI-defined monitor policy.
Configure a process event for a CLI-defined monitor policy.
Configure an SNMP-Notification event for a CLI-defined policy.
Create a CLI-defined EAA monitor policy and enter its view.
Suspend monitor policies.
Configure the runtime of a CLI-defined policy.
Display context information for process exceptions.
Display kernel thread deadloop information.
Display kernel thread exception information.
Display process state information.
Display log information for all processes.
Display heap memory usage for a process.
Specify the directory for saving core files.
Disable kernel thread deadloop detection for a kernel thread.
Display process statistics.
Enable/disable core file generation for exceptions and set max core files.
Clear kernel thread deadloop information.
Display sampler configuration information.
Create a sampler.
Display mirroring group information.
Create a mirroring group.
Configure a source port for a mirroring group.
Configure a port as the monitor port for a mirroring group.
Configure flow mirroring actions.
Configure and manage NetStream.
Display information about the NetStream data export.
Enable a NetStream aggregation mode.
Enable NetStream filtering on an interface.
Set an IPv6 NetStream aggregation mode and enter its view.
Limit the IPv6 NetStream data export rate.
Configure refresh frequency (in packets) for IPv6 NetStream version 9 templates.
Export IPv6 NetStream data in version 9 format, recording AS and BGP next hop info.
Set the aging timer for active flows.
Age out all flows in cache and export IPv6 NetStream data.
Display sFlow configuration and operation information.
Configure an IP address for the sFlow agent.
Configure parameters for an sFlow collector.
Specify an sFlow collector for counter sampling.
Set max bytes (from packet header) that flow sampling can copy per packet.
Enable flow sampling and specify packet count for sampling.
Manually save diagnostic logs from buffer to log file.
Display diagnostic log file configuration.
Display information center configuration information.
Display the summary of the log buffer.
Configure the interval for saving logs to a log file.
Configure the directory to save the diagnostic log file.
Enable the information center.
Enable log output to the log buffer.
Enable the log file feature.
Enable saving of security logs to the security log file.
Specify the security log file directory.
Specify a source IP address for logs sent to log hosts.
Enable saving of security logs to the security log file.
Set the maximum size for the security log file.
Set the lowest level of logs output to the current terminal.
Capture incoming packets on an interface.
Display the contents in a packet file.
Find worldwide technical support information on the HP support website.
Register product for email notification of enhancements, drivers, and firmware updates.
Describes conventions for commands: boldface, italic, brackets, braces, asterisk, ampersand, pound sign.
Describes conventions for GUI elements: boldface, angle brackets.
Describes symbols: WARNING, CAUTION, IMPORTANT, NOTE, TIP.
Notes that port numbers are for illustration and may be unavailable on your device.