SWEep Subsystem
Copyright © ITECH Electronic Co., Ltd. 105
Chapter20 SWEep Subsystem
SWEep:FUNCtion <mode>
This command is used to set Sweep mode.
AC mode: CC|CR
DC mode: CC|CP|CR
Syntax:
SWEep:FUNCtion <mode>
Arguments
CC|CR CC|CP|CR
*RST
0
Query syntax:
SWEep:FUNCtion?
Returns:
CC|CP|CR
Example
SWE:FUNC CC
SWEep:LEVel:STARt <NRf+>[,<NRf+>,<NRf+>]
This command is used to set and query the start value of Sweep.
<NRf+>: initial setting value, or initial MINimum or MAXimum or DEFault setting
Note:
In single-phase (including AC, ACDC, DC, DCAC), there is only one parameter;
in three-phase, three parameters must be taken.
Syntax:
SWEep:LEVel:STARt <NRf+>[,<NRf+>,<NRf+>]
Arguments
<NRf+>[,<NRf+>,<NRf+>]
*RST
0