EasyManuals Logo
Home>ITech>Measuring Instruments>IT8200 Series

ITech IT8200 Series Programming Guide

ITech IT8200 Series
137 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
Load Protect Subsystem
Copyright © ITECH Electronic Co., Ltd. 61
Returns:
MAXimum|MINimum|DEFault
Example
VOLTage:UNDer:PROTection 30
[SOURce:]VOLTage:UNDer:PROTection:DELay
<NRf+>
This command is used to set the undervoltage protection delay time in s. It only
needs to be set when in DC mode.
Syntax:
VOLTage:UNDer:PROTection:DELay <NRf+>
Arguments
<MINimum-MAXimum>
Query syntax:
VOLTage:UNDer:PROTection:DELay? [MAXimum|MINimum]
Returns:
<MINimum-MAXimum>
Example
VOLTage:UNDer:PROTection:DELay 1
[SOURce:]VOLTage:PEAK:PROTection[:LEVel] <NRf+>
Sets the upper voltage peak limit.
Syntax:
VOLTage:PEAK:PROTection[:LEVel] <NRf+>
Arguments
<MINimum-MAXimum>
Query syntax:
VOLTage:PEAK:PROTection[:LEVel]? [MAXimum|MINimum]
Returns:
<MINimum-MAXimum>
Example
VOLTage:PEAK:PROTection 350