SOURce Subsystem
Copyright © ITECH Electronic Co., Ltd. 62
Chapter15 SOURce Subsystem
[SOURce:]SYSTem:FUNCtion <CPD>
This command is used to set the mode of present load, including
single-phase/three-phase/reverse.
Syntax:
SYSTem:FUNCtion <CPD>
Arguments
ONE|THRee|DIFFerence
Default
ONE
Query syntax:
SYSTem:FUNCtion?
Returns:
ONE|THRee|DIFFerence
Example
SYST:FUNC ONE
[SOURce:]FUNCtion <CPD1>
This command is used to set load mode.
Syntax:
FUNCtion <CPD1>
Arguments
AC mode: CC|CR|CP|CS|CC+CR|CE
DC mode: CC|CR|CP|CV|CC+CV|CR+CV|CP+CV|CR+CC|CC+CR+CP+CV
Query syntax:
FUNCtion?
Returns:
AC mode: CC|CR|CP|CS|CC+CR|CE
DC mode: CC|CR|CP|CV|CC+CV|CR+CV|CP+CV|CR+CC|CC+CR+CP+CV