SYSTem Commands
Copyright © ITECH Electronic Co., Ltd. 4
Chapter4 SYSTem Commands
SYSTem:VERSion?
This command queries the SCPI version of the instrument.
Syntax
SYSTem:VERSion?
Arguments
None
Reset value
Not applicable
Example
- > SYST:VERS?
< - "1993.1"
Returns
SRD
SYSTem:ERRor?
This command reads the error code and error information.
Syntax
SYSTem:ERRor?
Arguments
None
Example
- > SYST:ERR?
< - 0,"NO_ERR"
Note
- >” indicates the commands that you send to instrument.
“< -” indicates the response from instrument.
SYSTem:PRESet
This command is used to make the instrument in a state suitable for panel
operation(reset).
Syntax
SYSTem:PRESet