SCOPe Subsystem
Copyright © ITECH Electronic Co., Ltd. 32
Query syntax
SCOPe:RECord:LENGth?
Example
SCOPe:RECord:LENGth 6
SCOPe:SAMPle:MODE <NORMal|PEAK>
This command is used to set sampling mode of Oscilloscope.
NORMal: Acquisition of data points by equal interval mode
PEAK: Acquisition of data points by peak-to-peak mode
Syntax
SCOPe:SAMPle:MODE <NORMal|PEAK>
Argument
<NORMal|PEAK>
Query syntax
SCOPe:SAMPle:MODE?
Example
SCOPe:RECord:LENGth 6
SCOPe:DATA:TAG?
Queries the sample data identification of the oscilloscope.
Syntax
SCOPe:DATA:TAG?
Returns
Return: <NR1>,<NR1> ,<NR1> ,<NR1> ,<NR1>
The first one is the starting point of the display
The second one shows the end time point
The third one is the data start time point
The fourth is the data end time point
The fifth is the data trigger time point
Example
SCOPe:DATA:TAG?