FETCh & MEASure Subsystem
Copyright © ITECH Electronic Co., Ltd. 33
Chapter12 FETCh & MEASure Subsystem
FETCh[:SCALar]:CURRent[:AC]?
MEASure[:SCALar]:CURRent[:AC]?
This command is used to read the RMS value of current.
Note: this command parameter is optional. If there is no parameter, it will return
the value of A, B, C three-phase by default.
Syntax:
FETCh[:SCALar]:CURRent? [A|B|C]
MEASure[:SCALar]:CURRent[:AC]? [A|B|C]
Arguments
[A|B|C]
Returns:
<NRf>…
Example
FETC:CURR? A
MEAS:CURR?
FETCh[:SCALar]:CURRent:DC?
MEASure[:SCALar]:CURRent:DC?
This command is used to read the DC component of current.
Note: this command parameter is optional. If there is no parameter, it will return
the value of A, B, C three-phase by default.
Syntax:
FETCh[:SCALar]:CURRent? [A|B|C]
MEASure[:SCALar]:CURRent:DC? [A|B|C]
Arguments
[A|B|C]
Returns:
<NRf>…