FETCh & MEASure Subsystem
Copyright © ITECH Electronic Co., Ltd. 35
FETCh[:SCALar]:CURRent[:AC][:AMPLitude]:MAXimum?
MEASure[:SCALar]:CURRent[:AC][:AMPLitude]:MAXimum?
This command is used to read the peak value of current.
Note: this command parameter is optional. If there is no parameter, it will return
the value of A, B, C three-phase by default.
Syntax:
FETCh[:SCALar]:CURRent[:AC][:AMPLitude]:MAXimum?
MEASure[:SCALar]:CURRent[:AC][:AMPLitude]:MAXimum?
Arguments
[A|B|C]
Returns:
<NRf>…
Example
FETC:CURR:MAX?
FETCh[:SCALar]:VOLTage[:AC][:AMPLitude]:MAXimum:HOLD?
MEASure[:SCALar]:VOLTage[:AC][:AMPLitude]:MAXimum:HOLD?
This command is used to read the peak voltage hold value of ABC. It will be
cleared automatically on the next power-on.
Note: this command parameter is optional. If there is no parameter, it will return
the value of A, B, C three-phase by default.
Syntax:
FETCh[:SCALar]:VOLTage[:AC][:AMPLitude]:MAXimum:HOLD?
MEASure[:SCALar]:VOLTage[:AC][:AMPLitude]:MAXimum:HOLD?
Arguments
[A|B|C]
Returns:
<NRf>…
Example
FETC:CURR:CFAC?

Table of Contents

Other manuals for ITech IT8200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8200 Series and is the answer not in the manual?

ITech IT8200 Series Specifications

General IconGeneral
BrandITech
ModelIT8200 Series
CategoryMeasuring Instruments
LanguageEnglish