FETCh & MEASure Subsystem
Copyright © ITECH Electronic Co., Ltd. 49
FETCh[:SCALar]:ARRay:CURRent:HARMonic[:AMPLitu
de]? <[A|B|C]>,<NR1>
MEASure[:SCALar]:ARRay:CURRent:HARMonic[:AMPLi
tude]? <[A|B|C]>,<NR1>
This command is used to measure each harmonic amplitude of the current.
Syntax:
FETCh[:SCALar]:ARRay:CURRent:HARMonic[:AMPLitude]? <[A|B|C]>,<NR1>
MEASure[:SCALar]:ARRay:CURRent:HARMonic[:AMPLitude]? <[A|B|C]>,<NR1>
Arguments
<[A|B|C]>,<NR1>
NR1 range: 0-50
Returns:
<NRf>
Example
FETC:ARR:CURR:HARM? A,6
FETCh[:SCALar]:ARRay:VOLTage:HARMonic:PHASe?
<[A|B|C]>,<NR1>
MEASure[:SCALar]:ARRay:VOLTage:HARMonic:PHASe?
<[A|B|C]>,<NR1>
This command is used to measure each harmonic phase of the voltage.
Syntax:
FETCh[:SCALar]:ARRay:VOLTage:HARMonic:PHASe? <[A|B|C]>,<NR1>
MEASure[:SCALar]:ARRay:VOLTage:HARMonic:PHASe? <[A|B|C]>,<NR1>
Arguments
<[A|B|C]>,<NR1>
NR1: 0-50
Returns:
<NRf>
Example
FETC:ARR:VOLT:HARM:PHAS? CH3,6