Measure Commands
Copyright © ITECH Electronic Co., Ltd. 36
Returns
<NR2> is the measured input power in watt.
Example
MEAS:POW? might return 5.01, which would be the
measured power across the electronic load inputs in watt.
MEASure:CAPability?
This command initiates and executes a new discharging capability
measurement, and returns the measured input discharging capability of the
electronic load.
Group
Measurement
Syntax
MEASure:CAPability?
Returns
<NR2>is the measured input discharging capability in
ampere-hour.
Example
MEAS:CAP? might return 5.011, which would be the
measured discharging capability of the electronic load in
ampere-hour.
MEASure:TIME?
This command initiates and executes a new discharging time measurement,
and returns the measured input discharging time of the electronic load.
Group
Measurement
Syntax
MEASure:TIME?
Returns
<NR2> is the measured discharging time in second.
Example
MEAS:TIME? might return 5.1, which would be the
measured discharging time of the electronic load in
second.

Table of Contents

Other manuals for ITech IT8800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8800 Series and is the answer not in the manual?

ITech IT8800 Series Specifications

General IconGeneral
BrandITech
ModelIT8800 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals