Source Subsystem
Copyright © ITECH Electronic Co., Ltd. 52
CONTinuous The transient generator puts out a continuous pulse stream
after receipt of a trigger.
PULSe The transient generator puts out a single pulse upon receipt of a
trigger.
TOGGle The transient generator toggles between two levels upon
receipt of a trigger.
Command Syntax [SOURce:] RESistance:TRANsient:MODE <mode>
Parameters CONTinuous | PULSe | TOGGle
*RST Value CONTinuous
Examples RES:TRAN:MODE TOGG
Query Syntax [SOURce:] RESistance:TRANsient:MODE?
Returned Parameters <CRD>
Related Commands RES:TRAN:ALEV TRAN
[SOURce:]RESistance:TRANsient:ALEVel
[SOURce:]RESistance:TRANsient:BLEVel
This command specifies the transient level of the resistance. The transient
function switches between the level a and level b.
Command Syntax [SOURce:] RESistance:TRANsient:ALEVel <NRf+>
[SOURce:] RESistance:TRANsient:BLEVel <NRf+>
Parameters MIN through MAX | MINimum | MAXimum | DEFault
Unit
*RST Value ALEVEL MAXimum , BLEVel MINnum
Examples RES:TRAN:ALEV 5 POW:TRAN:BLEV 0.5
Query Syntax [SOURce:] RESistance:TRANsient:ALEVel?
[ MINimum | MAXimum | DEFault ]
[SOURce:] RESistance:TRANsient:BLEVel?
[ MINimum | MAXimum | DEFault ]
Returned Parameters <NR3>
Related Commands RES
[SOURce:]RESistance:TRANsient:0
[SOURce:]RESistance:TRANsient:BWIDth
This command specifies the transient pulse width of the input resistance.
Command Syntax [SOURce:] RESistance:TRANsient:AWIDth <NRf+>
[SOURce:] RESistance:TRANsient:BWIDth <NRf+>
Parameters 50 to 3600 us
Unit S (second)
*RST Value 1000uS
Examples RES:TRAN:AWID 0.001 RES:TRAN:BLEV 0.02
Query Syntax [SOURce:] RESistance:TRANsient:AWIDth?
[ MINimum | MAXimum | DEFault ]
[SOURce:] RESistance:TRANsient:BWIDth?
[ MINimum | MAXimum | DEFault ]
Returned Parameters <NR3>
Related Commands RES