(2) Function list
• Level 1 (Refer to the instruction manual for changing procedure.)
No. Item Setting range
Initial value
SS HS SL HL HS
2516 2516 2516 2516 3020
HL
2516
FU
1 Maximum sewing speed 200 to 2800sti/min 100sti/min 2800
2 Sewing speed of 1st stitch 200 to 900sti/min 100sti/min 900
(In case of with thread clamp)
3 Sewing speed of 2nd stitch 200 to 2800sti/min 100sti/min 2800
(In case of with thread clamp)
4 Sewing speed of 3rd stitch 200 to 2800sti/min 100sti/min 2800
(In case of with thread clamp)
5 Sewing speed of 4th stitch 200 to 2800sti/min 100sti/min 2800
(In case of with thread clamp)
6 Sewing speed of 5th stitch 200 to 2800sti/min 100sti/min 2800
(In case of with thread clamp)
7 Thread tension of 1st stitch 0 to 200 1 200
(In case of with thread clamp)
8 Thread tension setting at the time 0 to 200 1 0
of thread trimming
9 Thread tension changeover timing –6 to 4 1 (4°)0
setup at the time of thread trimming
10 Sewing speed of 1st stitch 200 to 1500sti/min 100sti/min 200
In case of without thread clamp
11 Sewing speed of 2nd stitch 200 to 2800sti/min 100sti/min 600
In case of without thread clamp
12 Sewing speed of 3th stitch 200 to 2800sti/min 100sti/min 1000
In case of without thread clamp
13 Sewing speed of 4th stitch 200 to 2800sti/min 100sti/min 1500
In case of without thread clamp
14 Sewing speed of 5th stitch 200 to 2800sti/min 100sti/min 2000
In case of without thread clamp
– 83 –
SL
2516
FU
Smallest
change-
able unit