ELECTRICAL SYSTEM 68
601411-01
– Connect the battery charger to the battery. Switch on the battery charger.
Battery charger (58429074000)
You can also use the battery charger to test the open-circuit voltage and starting
voltage of the battery, and to test the alternator. With this device, you cannot over-
charge the battery.
Info
Only charge the battery with the specified battery charge.
This is the only way to ensure that a charging voltage of 14.4 V is not
exceeded.
– Switch off the battery charger after charging. Disconnect the battery.
– Mount the seat. ( p. 44)
12.4Changing the main fuse
Warning
Fire hazard The electrical system can be overloaded if the wrong fuses are used.
– Use only fuses with the prescribed amperage. Never by-pass or repair fuses.
Info
The main fuse protects all power consumers of the vehicle. It is located in the starter relay housing under the seat.
– Switch off all power consumers and switch off the engine.
– Remove the seat. ( p. 44)
601371-10
– Remove protection cap .
– Remove the faulty main fuse .
601372-10
– Fit a new main fuse.
Fuse (58011109130) ( p. 90)
Info
Replace a faulty fuse by an equivalent fuse only.
A reserve fuse is located in the starter relay.
– Check that the electrical equipment is functioning properly.
Tip
Insert the spare fuse so that it is available if needed.
– Attach the protection caps.
– Mount the seat. ( p. 44)