8.2.2 Basic seng and opons
8.2.2.1 Staon name and IP conguraon
The staon name and the IP conguraon can be assigned by the IO-Controller. These sengs
enable the IO-Controllerto idenfy the devices in the network and manage the data exchange.
The staon name and the IP conguraon can also be assigned by the »Engineering Tool«.
The staon name of the IO device must be entered with permissible characters according
to the PROFINET specicaon. 40x2381:004
Display of the currently used staon name: 40x2382:004
The IP conguraon comprises the assignments of:
IP address 40x2381:001
Subnet mask 40x2381:002
Gateway address 40x2381:003
Display of the actual IP conguraon: 40x2382:001 ... 0x2382:003
Save the staon name and the IP conguraon in the IO Device with line voltage
failure protecon so the IO Device can be idened via PROFINET if the IO
controller is switched o. 0x2022:003
4Saving the parameter sengs ^ 23
An invalid staon name or the assignment of invalid combinaons of the IP
address, subnet mask, and gateway address can have the consequence that no
connecon to PROFINET can be established.
In case of impermissible sengs, the red LED "bus ERR" is blinking and the error
message "PROFINET: Stack inializaon error [0x8192]" is output.
4LED status display ^ 78
Parameter
Address Name / seng range / [default seng] Informaon
0x2381:001 PROFINET sengs: IP address
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
Set IP address
A changed value will only be eecve aer the PROFINET
communicaon is restarted (0x2380 = 1).
0x2381:002 PROFINET sengs: Subnet
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
Set subnet mask
A changed value will only be eecve aer the PROFINET
communicaon is restarted (0x2380 = 1).
0x2381:003 PROFINET sengs: Gateway
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
Set gateway address
A changed value will only be eecve aer the PROFINET
communicaon is restarted (0x2380 = 1).
The gateway address is valid if the network address of the IP address
is idencal to the gateway address. In this case, no gateway
funconality is used.
DHCP is not supported.
0x2381:004 PROFINET sengs: Staon name Set staon name
A changed value will only be eecve aer the PROFINET
communicaon is restarted (0x2380 = 1).
0x2381:005 PROFINET sengs: I&M1 System designaon Input/output of the I&M1 system designaon
The default seng is an empty string.
0x2381:006 PROFINET sengs: I&M1 Installaon site Input/output of the I&M1 locaon idencaon code
The default seng is an empty string.
0x2381:007 PROFINET sengs: I&M2 Installaon date Input/output of the I&M2 date of installaon
The default seng is an empty string.
0x2381:008 PROFINET sengs: I&M3 addional informaon Input/output of the I&M3 addional informaon
The default seng is an empty string.
Conguring the network
PROFINET
Basic seng and opons
74

Table of Contents

Other manuals for Lenze C520

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze C520 and is the answer not in the manual?

Lenze C520 Specifications

General IconGeneral
BrandLenze
ModelC520
CategoryController
LanguageEnglish

Related product manuals