8.2.2.2 Suppress diagnosc messages to the IO controller
40x285A:001 serves to set which error response in the device suppresses the alarm message
to the IO-Controller.
Parameter
Address Name / seng range / [default seng] Informaon
0x285A:001 Diagnosc conguraon: Alarm supression
0x0000 ... [0x0000] ... 0xFFFF
Bit coded selecon of error responses which suppress the alarm
message to the IO controller.
•
Bit x = 1 = suppress alarm message.
•
In the default seng "0", an alarm message is displayed for all error
responses.
Bit 1 Warning
Bit 2 Warning locked
Bit 3 Trouble
Bit 4 Fault > Applicaon quick stop > Quick stop
8.2.3 Process data transfer
Process data serve to control the device.
•
The process data is transmied cyclically between the IO-Controller and the IO-Devices
parcipang in PROFINET.
•
The process data can be directly accessed by the IO controller. The data in the PLC, for
instance, are directly stored in the I/O area.
•
The length of the process data is 1 ... 250 bytes (max. 244 slots) per direcon.
•
The process data is transmied 1 : 1 according to its sequence.
Conguring the network
PROFINET
Process data transfer
75